IOy Ethernet I/O

BL191 PROFINET IOy Ethernet IO

Item No.: BL191
PROFINET Remote IO
Introduction Features Specifications Download Applications
BL191 PROFINET Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select the I/O modules by physical interfaces, protocols, and I/O functions.
The PROFINET Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.


Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL191 with 3 Y11 (8DI) can be composed of 24DI PROFINET IO module, and also supports mix and match such as BL191 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT PROFINET IO Module.

Naming Rules  
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y


Example
BL191-Y11 PROFINET Protocol 8DI I/O Module
BL191-Y11-Y11 PROFINET Protocol 16DI I/O Module
BL191-Y11-Y11-Y11 PROFINET Protocol 24DI I/O Module
BL191-Y11-Y21-Y31 PROFINET Protocol 8DI+8DO+4AI I/O Module

Optional Protocols
BL190 Modbus TCP 
BL191 PROFINET
BL192 EtherCAT
BL193 Ethernet/IP
BL195 OPC UA
BL196 MQTT
BL197 SNMP
BA190 BACnet/IP
BE190 IEC104

Optional I/O Boards
IO Item no. Function Description
Y11 8DI NPN Logic 1: -3 ⋯ +5VDC; Logic 0: +15 ⋯ +30VDC
Y12 8DI PNP Logic 1: +15 ⋯ +30VDC; Logic 0: -3 ⋯ +5VDC
Y21 8DO PNP Logic 1: 24 VDC; Logic 0: High impedance
Y22 8DO NPN Logic 1: 0 VDC; Logic 0: High impedance
Y24 4DO Relay Max voltage: 250VAC/30VDC; Max current: 2A
Y01 4DI+4DO NPN DI wet or dry contact, DO NPN
Y02 4DI+4DO PNP DI wet or dry contact, DO PNP
Y03 4DI+4DO Relay DI wet or dry contact, DO relay output
Y31 4AI 0/4-20mA Single-Ended 0~20mA, 4~20mA analog input, resolution: 16 Bit
Y33 4AI 0-5/10V Single-Ended 0~5V, 0~10V analog input, resolution: 16 Bit
Y34 4AI 0-5/10V Differential 0~5V, 0~10V analog input, resolution: 16 Bit
Y36 4AI ±5V/±10V Differential -5~5V, -10~10V analog input, resolution: 16 Bit
Y41 4AO 0/4-20mA 0~20mA, 4~20mA analog output, resolution: 16 Bit
Y43 4AO 0-5/10V 0~5V, 0~10V analog output, resolution: 16 Bit
Y46 4AO ±5V/±10V -5~5V, -10~10V analog output, resolution: 16 Bit
Y51 2RTD 3-Wire PT100 3-wire PT100
Y52 2RTD 3-Wire PT1000 3-wire PT1000
Y53 2RTD 4-Wire PT100 4-wire PT100
Y54 2RTD 4-Wire PT1000 4-wire PT1000
Y56 Resistance Measurement -
Y57 Voltage Measurement -
Y58 4TC B/E/J/K/N/R/S/T Thermocouple
Y91 4High Speed Counter -
Y61 4RS485/RS232 -
Y62 1CAN+3RS485/RS232 -

 
Description
BL191 PROFINET Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select the I/O modules by physical interfaces, protocols, and I/O functions.
The PROFINET Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.


Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL191 with 3 Y11 (8DI) can be composed of 24DI PROFINET IO module, and also supports mix and match such as BL191 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT PROFINET IO Module.

Naming Rules  
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y


Example
BL191-Y11 PROFINET Protocol 8DI I/O Module
BL191-Y11-Y11 PROFINET Protocol 16DI I/O Module
BL191-Y11-Y11-Y11 PROFINET Protocol 24DI I/O Module
BL191-Y11-Y21-Y31 PROFINET Protocol 8DI+8DO+4AI I/O Module

Optional Protocols
BL190 Modbus TCP 
BL191 PROFINET
BL192 EtherCAT
BL193 Ethernet/IP
BL195 OPC UA
BL196 MQTT
BL197 SNMP
BA190 BACnet/IP
BE190 IEC104

Optional I/O Boards
IO Item no. Function Description
Y11 8DI NPN Logic 1: -3 ⋯ +5VDC; Logic 0: +15 ⋯ +30VDC
Y12 8DI PNP Logic 1: +15 ⋯ +30VDC; Logic 0: -3 ⋯ +5VDC
Y21 8DO PNP Logic 1: 24 VDC; Logic 0: High impedance
Y22 8DO NPN Logic 1: 0 VDC; Logic 0: High impedance
Y24 4DO Relay Max voltage: 250VAC/30VDC; Max current: 2A
Y01 4DI+4DO NPN DI wet or dry contact, DO NPN
Y02 4DI+4DO PNP DI wet or dry contact, DO PNP
Y03 4DI+4DO Relay DI wet or dry contact, DO relay output
Y31 4AI 0/4-20mA Single-Ended 0~20mA, 4~20mA analog input, resolution: 16 Bit
Y33 4AI 0-5/10V Single-Ended 0~5V, 0~10V analog input, resolution: 16 Bit
Y34 4AI 0-5/10V Differential 0~5V, 0~10V analog input, resolution: 16 Bit
Y36 4AI ±5V/±10V Differential -5~5V, -10~10V analog input, resolution: 16 Bit
Y41 4AO 0/4-20mA 0~20mA, 4~20mA analog output, resolution: 16 Bit
Y43 4AO 0-5/10V 0~5V, 0~10V analog output, resolution: 16 Bit
Y46 4AO ±5V/±10V -5~5V, -10~10V analog output, resolution: 16 Bit
Y51 2RTD 3-Wire PT100 3-wire PT100
Y52 2RTD 3-Wire PT1000 3-wire PT1000
Y53 2RTD 4-Wire PT100 4-wire PT100
Y54 2RTD 4-Wire PT1000 4-wire PT1000
Y56 Resistance Measurement -
Y57 Voltage Measurement -
Y58 4TC B/E/J/K/N/R/S/T Thermocouple
Y91 4High Speed Counter -
Y61 4RS485/RS232 -
Y62 1CAN+3RS485/RS232 -

 
introduction
Features
Specifications
Download
Applications

Review